Propuesta de una Guía de Diseño para Conexiones Tipo Bolted Flange Plate (BFP) en Estructuras Metálicas Industriales con Sistema IMF, basada en Normativa Americana y aplicada al contexto sísmico de Lima, Perú
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Issue Date
2025-06-14Keywords
Edificio metálico industrialBolted Flange Plate (BFP)
Intermediate Moment Frame (IMF)
Normativas
Industrial steel structure
Design codes
Metadata
Show full item recordOther Titles
Design Guide Proposal for Bolted Flange Plate (BFP) Connections in IMF Industrial Structures, Based on American Standards and Applied to the Seismic Context of Lima, PeruAbstract
La industria en el Perú ha experimentado un crecimiento significativo, lo que ha impulsado el desarrollo de modernas edificaciones metálicas en la industria. Bajo estas circunstancias, este informe de investigación tiene como finalidad proponer un manual de diseño para conexiones tipo Bolted Flange Plate (BFP) en estructuras metálicas industriales que emplean el sistema Intermediate Moment Frame (IMF), basándose en normativa estadounidense y adaptándola al contexto sísmico de Lima, mediante el uso de un caso práctico como ejemplo. Este enfoque se justifica debido a que la normativa sísmica peruana vigente no contempla disposiciones específicas relativas a estas conexiones estructurales. Se expone un compendio de información que define los criterios indispensables para la elaboración de la propuesta de guía de diseño de conexiones tipo BFP en estructuras metálicas industriales con sistema IMF. Como parte de la aplicación práctica, se plantea el diseño teórico de un edificio metálico industrial de 296 m², compuesto por dos niveles y cinco pórticos por nivel, separados por una distancia de 6 metros, con el fin de aplicar la metodología desarrollada. La metodología propuesta cumple con los criterios establecidos en el Reglamento Nacional de Edificaciones (RNE) y en las normas del American Institute of Steel Construction (AISC). Finalmente, se elaboraron el modelo estructural en SAP2000 y el diseño de las conexiones tipo BFP conforme a las especificaciones de las normas AISC.The industrial sector in Peru has experienced significant growth, creating the need for the development of new industrial steel structures. Under these circumstances, this research report aims to propose a design manual for Bolted Flange Plate (BFP) connections in industrial steel structures utilizing the Intermediate Moment Frame (IMF) system., based on American standards and adapted to the seismic context of Lima, using a practical case study as an example. This approach is justified by the fact that the current Peruvian seismic code does not include specific provisions for this type of structural connection. A compilation of theoretical information is presented, establishing the necessary guidelines for the development of the proposed design guide for BFP connections in industrial steel structures using the IMF system. As part of the practical application, the theoretical design of a 296 m² industrial steel building is proposed. The structure consists of two levels and five frames per level, spaced 6 meters apart, in order to apply the developed methodology. The proposed methodology complies with the requirements established in the Reglamento Nacional de Edificaciones (RNE) and the standards of the American Institute of Steel Construction (AISC). Finally, the structural model was developed in SAP2000, and the design of the BFP connections was carried out in accordance with AISC standards.
Type
info:eu-repo/semantics/bachelorThesisRights
info:eu-repo/semantics/openAccessLanguage
spaCollections


