Show simple item record

dc.contributor.authorBocanegra, Fabiana
dc.contributor.authorCervantes, Romina
dc.contributor.authorCasas, Joan R.
dc.contributor.authorDelgadillo, Rick M.
dc.date.accessioned2025-01-07T15:54:28Z
dc.date.available2025-01-07T15:54:28Z
dc.date.issued2025-01-01
dc.identifier.issn23662557
dc.identifier.doi10.1007/978-981-97-5477-9_28
dc.identifier.urihttp://hdl.handle.net/10757/683810
dc.description.abstractStructural damage not only causes material losses but also human losses, especially in the case of essential buildings such as health facilities, as they must ensure the provision of medical services during and after an earthquake. On the other hand, Peru is a highly seismic country due to its location on the western edge of South America, an area where the Nazca and South American tectonic plates converge. For this reason, it is essential to reinforce these infrastructures with devices that help prevent and reduce damage caused by earthquakes and guarantee the safety of the hospital. This paper studies the seismic performance of three energy dissipators: Shear Link Bozzo (SLB), Triangular Plate Added Damping and Stiffness (TADAS) and viscous fluid; incorporated into an existing hospital in Peru. The methodology involves modeling these three devices using ETABS software and evaluating the following study cases: (i) without energy dissipators, (ii) with the three seismic devices evaluated separately. Non-linear time-history analysis is conducted, considering seven seismic records compatible with the response spectrum constructed from the parameters of the Peruvian Standard E.030. Finally, it was concluded that the viscous fluid dissipator is the best option to implement in the hospital since the maximum drifts, accelerations and shear forces on each floor were reduced by 45, 23 and 27%.es_PE
dc.formatapplication/htmles_PE
dc.language.isoenges_PE
dc.publisherSpringer Science and Business Media Deutschland GmbHes_PE
dc.rightsinfo:eu-repo/semantics/embargoedAccesses_PE
dc.subjectEnergy dissipatorses_PE
dc.subjectHospitalses_PE
dc.subjectSeismic performancees_PE
dc.subjectShear Link Bozzo (SLB)es_PE
dc.subjectTriangular plate added damping and stiffness (TADAS)es_PE
dc.subjectViscous fluid dissipatorses_PE
dc.titleComparative Study of Seismic Performance of SLB, TADAS and Viscous Fluid Energy Dissipators in Hospitalses_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.identifier.eissn23662565
dc.identifier.journalLecture Notes in Civil Engineeringes_PE
dc.identifier.eid2-s2.0-85210513048
dc.identifier.scopusidSCOPUS_ID:85210513048
dc.source.journaltitleLecture Notes in Civil Engineering
dc.source.volume534 LNCE
dc.source.beginpage347
dc.source.endpage357
dc.identifier.isni0000 0001 2196 144X
dc.description.odsODS 3: Salud y bienestar
dc.description.odsODS 9: Industria, innovación e infraestructura
dc.description.odsODS 17: Alianzas para lograr los objetivos


This item appears in the following Collection(s)

Show simple item record