Sistema de Masa Sintonizada para la mejora de la respuesta sísmica del pabellón modelo Apenkai de la Institución Educativa 6075 José maría Arguedas
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Advisors
Moreno Sanchez, Javier DanielIssue Date
2024-09-03Keywords
Sistema de control pasivosAMS
Protección sísmica
Colegios nacionales
Irregularidad estructural
Efecto torsional
Seismic Control passive
TMD
Seismic protection
National colleges
Structural irregularity
Torsional effect
Metadata
Show full item recordOther Titles
Tuned Mass Damper to improve the seismic response of the Apenkai model pavilion of the Educational Institution 6075 Jose Maria ArguedasAbstract
Ante el posible peligro sísmico vigente en la ciudad de Lima, las edificaciones esenciales como colegios deben soportar sismos de gran magnitud. El uso de estas edificaciones debe cumplir como albergue ante posible movimiento telúrico. Uno de estos es el pabellón modelo Apenkai de la I. E. 6075 José María Arguedas de la ciudad de Lima. Esta edificación está compuesta de dos módulos, los cuales son un octogonal y un rectangular. Cada uno de estos módulos tiene tres niveles, el módulo octogonal tiene un aula por nivel y el módulo rectangular tiene 4 aulas por nivel. Esta estructura tiene como particularidades diversas irregularidades, una de ella es el efecto torsional de la estructura. Dicho efecto, puede ser causante de múltiples daños estructurales severos. No obstante, estos colegios fueron construidos con el RNE del año 1970, el cual subestimaban el análisis sísmico de las estructuras de esta época. La presente tesis se enfoca en evaluar la estructura mediante un análisis modal espectral y tiempo historia, a fin de analizar el efecto torsional de la estructura ante un sismo severo. Ante ello, la propuesta en el presente trabajo de tesis es reducir el efecto torsional de la estructura con amortiguadores de masas sintonizadas, y con ello cumplir los requisitos de la normativa peruana actual.Given the possible seismic danger in the city of Lima, essential buildings such as schools must withstand earthquakes of great magnitude. The use of buildings must comply as a shelter against possible earthquakes. One of these is the Apenkai model pavilion of the I.E., 6075 Jose María Arguedas of the city of Lima. This building is made up of two modules, one octagonal and one rectangular. Each of these modules has three levels, the octagonal module has one classroom per level and the rectangular module has 4 classrooms per level. This structure has various irregularities as particularities, one of which is the torsional effect of the structure. This effect can cause multiple severe structural damages. However, these schools were built with the RNE of the year 1970, which underestimated the seismic analysis of the structures of that time. This thesis focuses on evaluating the structure through spectral modal analysis and time history to see the torsional effect of the structure in the event of a severe earthquake. Given this, the proposal in this thesis is to mitigate the torsional effect of the structure with tuned mass dampers, and thereby meet the requirements of current Peruvian regulations.