Influencia de la Tabiquería en el Análisis Sísmico de un Edificio de Concreto Armado de 3 Pisos y Azotea en El Distrito de San Martín De Porres
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Advisors
Moreno Sánchez, Javier DanielIssue Date
2024-06-27Keywords
Tabiquería de arcillaTabiquería
Análisis sísmico estático
Puntal diagonal
Interacción estructura-tabiquería
Mansory
Infill walls
Static seismic análisis
Diagonal strut
Interaction structure partition
Metadata
Show full item recordOther Titles
Influence of partition walls on the seismic analysis of a 3-story reinforced concrete building with rooftop in the district of San Martín de PorresAdditional Links
https://audio.com/raupc/audio/950Abstract
En el Perú, la interacción entre tabiques y estructuras es una práctica común, motivada por la ausencia de regulaciones hasta antes del año 1996, junto con malas prácticas constructivas y la prevalencia de la informalidad en el sector. El presente documento se centra en analizar la influencia de 2 tipos de tabiquería en una vivienda de 3 niveles y azotea. Las unidades para analizar son ladrillos de arcilla tipo pandereta artesanal y pandereta industrial, además se sigue la norma peruana para su análisis y representación. Se presenta el proceso de modelamiento de los tabiques a través del puntal diagonal y se realiza un análisis sísmico estático y dinámico. Los resultados revelan un cambio significativo de rigidez entre los pisos 1 y 2, indicando la presencia de un posible piso blando en la estructura. Este análisis contribuye a comprender la influencia de los tabiques en la respuesta estructural de las edificaciones, especialmente en contextos donde su interacción es común y puede afectar la seguridad y estabilidad del inmueble.In Peru, the interaction between partition walls and structures is a common practice, motivated by the absence of regulations until before the year 1996, along with poor construction practices and the prevalence of informality in the sector. This document focuses on analyzing the influence of 2 types of partition walls in a 3-level house with a rooftop. The units for analysis are handmade clay bricks and industrial bricks, following the Peruvian standard for their analysis and representation. The process of modeling the partition walls through diagonal bracing is presented, and a static and dynamic seismic analysis is conducted. The results reveal a significant stiffness change between floors 1 and 2, indicating the presence of a possible soft story in the structure. This analysis contributes to understanding the influence of partition walls on the structural response of buildings, especially in contexts where their interaction is common and can affect the safety and stability of the property.
Type
info:eu-repo/semantics/bachelorThesisLanguage
spaEmbedded videos
Collections
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by-nc-sa/4.0/


