Análisis sísmico y diseño estructural en muros de albañilería, columnas y vigas en pabellón de colegio I.E. 1182 el bosque San Juan de Lurigancho -2023
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Issue Date
2023-11-12Keywords
Análisis sísmicoDiseño estructural
Muros de albañilería
Columnas
Vigas
Seismic analysis
Structural design
Masonry walls
Columns
Beams
Metadata
Show full item recordAbstract
La presente investigación cumple el objetivo determinar el análisis sísmico y diseño estructural en muros de albañilería columnas y vigas en pabellón del colegio E.E. 1182 el bosque San Juan de Lurigancho-2023. Para ello se realizará el método experimental, ya que se estudiará el diseño de su estructura, partiendo del plano arquitectónico, donde se observa los ambientes destinados en el pabellón “A” con aulas de dimensión 6.38m de ancho por 26.21m de largo, contando con 3 aulas por piso, habiendo considerado un solo pabellón de 3 niveles en esta investigación. El análisis estructural se llevó a cabo del estudio de mecánica de suelo, de ello se realizó el modelo estructural mediante el software Etabs 2019, para observar la sistematización del colegio, el software Excel para interpretar las características del análisis de muros de albañilería, columnas y vigas.The present investigation fulfills the objective of determining the seismic analysis and structural design of masonry walls, columns and beams in the pavilion of the E.E. school. 1182 the San Juan de Lurigancho forest-2023. To do this, the experimental method will be carried out, since the design of its structure will be studied, starting from the architectural plan, where the environments destined for pavilion “A” can be observed with classrooms measuring 6.38m wide by 26.21m long, counting with 3 classrooms per floor, having considered a single 3-level pavilion in this research. The structural analysis was carried out from the study of soil mechanics, from which the structural model was carried out using the Etabs 2019 software, to observe the systematization of the school, the Excel software to interpret the characteristics of the analysis of masonry walls, columns and beams.
Type
info:eu-repo/semantics/bachelorThesisRights
info:eu-repo/semantics/openAccessLanguage
spaCollections