Evaluación Numérica al volteo de un muro de una habitación inca del templo del Coricancha Cusco con encajes y sin encajes.
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Advisors
Lipa Cusi, LeonelIssue Date
2023-11-14Keywords
Construcciones incasImperio incaico
Etructuras incas
Teoría de los elementos finitos
Coeficiente de fricción
Inca constructions
Inca Empire
Inca structures
Finite element theory
Coefficient of friction
Metadata
Show full item recordOther Titles
Numerical evaluation of the overturning of a wall of an Inca room of the temple of Coricancha cusco with lace and without laceAbstract
En la actualidad muchas construcciones incas han desaparecido debido a la caída del imperio incaico y a la construcción de nuevos templos en la época colonial. Sin embargo, todavía hay estructuras incas que siguen de pie a pesar de su antigüedad. Por esa razón, este trabajo de investigación tiene por finalidad evaluar este tipo de sistemas haciendo uso de la teoría de los elementos finitos y definir si es posible modelar estas estructuras, de modo que sirva como punto de partida para futuras investigaciones. En la investigación se analiza dos muros incas de dos capas, uno con encaje y el otro sin encajes. Los muros con dimensiones 9.90 m x 2.8 m de altura de sección y 0.80 m, con densidad 2300 kg/m3, con una rigidez normal de 2 x 〖10〗^7 N/m3 , coeficiente de fricción 0.4 y los resultados obtenidos fueron el muro con encaje soporta un ángulo de 16.4°, mientras que el muro sin encaje soporta un ángulo el 10.4° se concluyó que el muro inca con encajes resiste más al volteo a diferencia del muro sin encajes.Today many Inca constructions have disappeared due to the fall of the Inca empire and the construction of new temples in colonial times. However, there are still Inca structures that are still standing despite their age. For that reason, the purpose of this research work is to evaluate this type of systems using the finite element theory and to define if it is possible to model these structures, in order to serve as a starting point for future research. The research analyzes two two-layer Inca walls, one with sockets and the other without sockets. The walls with dimensions 9.90 m x 2.8 m section height and 0.80 m, with density 2300 kg/m3, with a normal stiffness of 2 x 10^7 N/m3, friction coefficient 0.4 and the results obtained were that the wall with lace supports an angle of 16.4°, while the wall without lace supports an angle of 10.4°. It was concluded that the Inca wall with lace resists overturning more than the wall without lace.
Type
info:eu-repo/semantics/bachelorThesisRights
info:eu-repo/semantics/openAccessLanguage
spaCollections