Propuesta de reforzamiento estructural en muros usando láminas y anclajes de CFRP en comparación con mallas electrosoldadas en Instituciones Educativas mayores a 30 años de antigüedad
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Issue Date
2023-08-30Keywords
RefuerzoLáminas de CFRP
Muro de mampostería
Anclajes CFRP
Malla soldada
Reinforcement
CFRP sheets
Masonry wall
CFRP anchors
Welded mesh
Metadata
Show full item recordOther Titles
Proposal for structural reinforcement in walls with CFRP sheets and anchors compared to electro-welded mesh in Educational Institutions older than 30 yearsAbstract
En este presente proyecto de investigación, se presentan propuestas de reforzamiento con método convencional mediante el uso Mallas electrosoldadas Q-106 y método no convencional mediante el uso de láminas y anclajes CFRP para la estructura del modelo Apenkai 780. La investigación se enfoca en la Institución Educativa Jorge Basadre N° 6048 en el distrito de Villa el Salvador, el cual se ubica en una zona altamente sísmica. Cabe mencionar que el modelo Apenkai fue construido entre los años 1990 a 1995 en el periodo de gobierno de Alberto Fujimori que fueron realizadas con donaciones mediante la ONG APENKAI. Por ende, se realiza el análisis sísmico en su estado Asbuilt según las normas actuales N.T.P E030, E0.20, E0.70: con la finalidad de determinar que muros requieren reforzar y analizar el comportamiento sísmico de la estructura. Con los reforzamientos propuestos (Láminas y anclajes de CFRP y mallas electrosoldadas) se determinó que ambas propuestas incrementan la rigidez lateral y aumenta la capacidad de corte en los muros de albañilería frente a amenazas sísmicas. La investigación nos permite demostrar que el reforzamiento con láminas y anclajes CFRP alcanza un incremento de resistencia a corte en un 53.93% respecto a las mallas electrosoldadas. Por último, se realiza una estimación de costo y tiempo de ambas propuestas; donde las láminas y anclajes de CFRP por su proceso fácil y rápido de instalación se realiza en menor tiempo en comparación con las mallas electrosoldadas.In this research project, reinforcement proposals are presented with the conventional method through the use of Q-106 electrowelded meshes and the non-conventional method through the use of CFRP sheets and anchors for the Apenkai 780 model structure. The research focuses on the Educational Institution Jorge Basadre No. 6048 in the district of Villa el Salvador, which is located in a highly seismic zone. It is worth mentioning that the Apenkai model was built between 1990 and 1995 during the government of Alberto Fujimori, which was carried out with donations through the NGO APENKAI. Therefore, the seismic analysis is performed in its Asbuilt state according to the current standards N.T.P E030, E0.20, E0.70: in order to determine which walls, require reinforcement and analyze the seismic behavior of the structure. With the proposed reinforcements (CFRP sheets and anchors and electro-welded meshes) it was determined that both proposals increase lateral stiffness and increase the shear capacity of masonry walls against seismic threats. The research allows us to demonstrate that the reinforcement with CFRP mines and anchors reaches an increase in shear strength of 53.93% compared to electro-welded meshes. Finally, an estimate of cost and time of both proposals is made; where CFRP sheets and anchors, due to their easy and fast installation process, are carried out in less time compared to electro-welded m
Type
info:eu-repo/semantics/bachelorThesisRights
Attribution-NonCommercial-ShareAlike 4.0 Internationalinfo:eu-repo/semantics/openAccess
Language
spaCollections
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 4.0 International


