Factor de amplificación por la influencia del efecto tri-direccional del movimiento del suelo para el análisis estructural
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Advisors
Fernández Dávila Gonzales, Víctor IvánIssue Date
2021-08-31Keywords
Tri-direccionalSismo
Espectro
Parámetros dinámicos
Tri-directional ground motion
Vertical component
Seismic analysis
Dynamic parameters
Incidence angles
Metadata
Show full item recordOther Titles
Amplification factor by the influence of the three-directional ground montions for structural analysisAbstract
En la práctica profesional de la ingeniería civil, generalmente, se consideran los componentes del movimiento del suelo de forma independiente y desestimando la componente vertical en los análisis sísmicos. Sin embargo, ya existen estudios que invalidan dichos supuestos, y, es por tal, que el análisis sísmico debería considerar el efecto de todas las componentes del sismo a fin de estimar cualquier respuesta en la estructura. En este estudio se propondrán factores de amplificación para los espectros generados por los análisis uni-direcconales, con el fin de extenuar el efecto tri-direccional del sismo. Dichos factores se realizarán por medio del análisis de 54 estructuras caracterizadas por distintos parámetros dinámicos. Y, además, utilizando ángulos de incidencia cada 10° y 11 registros sísmicos para el ATH. Las respuestas máximas se compararán con las del espectro propuesto por la Norma E0.30 [1], obteniendo así reglas lineales para los factores de amplificación.In the professional practice of civil engineering, generally, the components of the ground movement are considered independently and disregarding the vertical component in seismic analyzes. However, there are already studies that invalidate these assumptions, and, therefore, the seismic analysis should consider the effect of all the components of the earthquake in order to estimate any response in the structure. In this study, amplification factors will be proposed for the spectra generated by the uni-directional analyzes, in order to exhaust the tri-directional effect of the earthquake. Said factors will be carried out through the analysis of 54 structures characterized by different dynamic parameters. And, in addition, using incidence angles every 10 ° and 11 seismic records for the ATH. The maximum responses will be compared with those of the spectrum proposed by Standard E0.30, thus obtaining linear rules for the amplification factors.
Type
info:eu-repo/semantics/bachelorThesisRights
info:eu-repo/semantics/openAccessLanguage
spaCollections
The following license files are associated with this item:
- Creative Commons