Análisis de la implementación de disipadores fluido-viscosos en el comportamiento torsional de una edificación de 5 niveles localizada en Lima
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Advisors
Vargas Bejarano, Cesar IsidoroIssue Date
2021-04-14Keywords
IrregularidadComportamiento torsional
Respuesta estructural
Dispositivos de energía
Amortiguamiento
Irregularity
Torsional behavior
Structural response
Power devices
Damping
Metadata
Show full item recordOther Titles
Analysis of the implementation of viscous fluid dissipators in the torsional behavior of a 5-level building located in LimaAbstract
El presente trabajo, consiste en la implementación de estos disipadores fluido-viscosos en una edificación con predominación de muros estructurales de 5 niveles que presenta un comportamiento torsional. El diseño de estos disipadores, parten con el objetivo de diseño de daño moderado y bajo un sismo de 475 años de periodo de retorno, es decir que la deriva objetivo necesario para el diseño es 0.58%. Se analiza bajo la colocación en diagonal para amortiguadores lineales y no lineales. La colocación se hace de manera uniforme, y de manera que compense el movimiento torsional. Se colocaron un total de 40 disipadores en todo el edificio. Entre los principales resultados, la fuerza fuerzas en los disipadores fueron en un orden de 213 ton-f y comportamiento torsional debido a zonas frágiles de la estructura fueran reducidas en 80%. La implementación de los disipadores fluido-viscosos permiten reducir la deriva en 60% y todas las derivas se mantienen por debajo de 0.58%, en teoría. En un futuro, en el Perú, será necesario implementar una normativa para el diseño y el aporte de amortiguamiento en el edificio.The present work consists of the implementation of these fluid-viscous dissipators in a building with a predominance of structural walls, of 5 levels that presents a torsional behavior, as well as fails to comply with the permissible drift limit established by Norma Técnica E.030. The design of these dissipators starts with the design objective of moderate damage and under an earthquake of 475 years of return period, whose corresponding objective drift assumes a value of 0.58%. It is discussed under diagonal placement for linear and nonlinear dampers. The placement is done uniformly, and in a way that compensates for torsional movement. A total of 40 heatsinks were placed throughout the building, 8 per floor. Among the main results, the forces in the dissipators were in the order of 200 ton-f and torsional behavior due to flexible areas of the structure were reduced by 80%. The implementation of fluid-viscous heatsinks allows the drift to be reduced by 60%, and all drifts are kept below 0.58%, that is, both linear and non-linear devices meet the target drift, even though the latter have a higher drift, given their lower C, therefore, lower force, less drift control, even so, they are efficient, both structurally and economically, given their lower strength. In the future, in Peru, it will be necessary to implement a regulation for the design and the cushioning contribution in the building.