Desempeño sísmico de una edificación de concreto armado dual mediante el análisis no lineal en el tiempo ubicado en el distrito de Lince, departamento de Lima-Perú
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Issue Date
2021-02-12Keywords
Desempeño sísmicoModelo computacional
Irregularidad geométrica
Norma sísmica
Seismic performance
Computational model
Geometric irregularity
Seismic standard
Metadata
Show full item recordOther Titles
Seismic performance of a reinforced concrete building through nonlinear análisis over timeAbstract
El tema de esta investigación aborda el desempeño sismorresistente de un edificio en Lima aplicando el análisis dinámico no lineal “Tiempo historia”. Por ello, la hipótesis plantea que el desempeño sísmico de un edificio destinado a vivienda en la ciudad de Lima debido a un sismo moderado y severo, cumple con lo indicado en la Norma Peruana Sismorresistente E-030 respecto a sus objetivos del no daño estructural y el no colapso respectivamente, si los puntos de desempeño obtenidos al comparar la curva de Capacidad con la curva de Demanda de la Norma E-030 se encuentran dentro del rango de desempeño establecido según el código de la Agencia Federal para el Manejo de Emergencias (FEMA). Consecuentemente, la investigación está dividida en 5 capítulos. En el primero, se presenta la descripción de la estructura a analizar, que abarca sus características arquitectónicas y estructurales. En el segundo, se expone una serie de conceptos fundamentales plasmados en el marco teórico, para entender el desempeño sísmico y todo lo relacionado con este análisis. En el tercero y cuarto, se realiza la evaluación del desempeño sismorresistente aplicando el Análisis Dinámico No lineal Tiempo Historia. Finalmente, se verificará si el desempeño sismorresistente de un edificio de albañilería confinada en la ciudad de Lima cumple o no con los objetivos de la Norma Peruana Sismorresistente E-030 2019.The subject of this research deals with the seismic performance of a building in Lima applying the non-linear dynamic analysis "Time History". Therefore, the hypothesis states that the seismic performance of a building intended for housing in the city of Lima due to a moderate and severe earthquake, complies with the provisions of the Peruvian Seismic E-030 Standard regarding its objectives of structural and non-structural damage. the non-collapse respectively, if the performance points obtained when comparing the Capacity curve with the Demand curve of the E-030 Standard are within the performance range established according to the code of the Federal Emergency Management Agency (FEMA). Consequently, the investigation is divided into 5 chapters. In the first one, the description of the structure to be analyzed is presented, which covers its architectural and structural characteristics. In the second, a series of fundamental concepts embodied in the theoretical framework is exposed to understand the seismic performance and everything related to this analysis. In the third and fourth, the evaluation of the seismic performance is performed applying the dynamic nonlinear analysis Time History. Finally, it will be verified if the seismic performance of a reinforced concrete building in the city of Lima complies or not with the objectives of the Peruvian Seismic Standard E-030 2019.
Type
info:eu-repo/semantics/bachelorThesisRights
info:eu-repo/semantics/openAccessLanguage
spaCollections
The following license files are associated with this item:
- Creative Commons