Show simple item record

dc.contributor.advisorHuaco Cárdenas, Guillermo David
dc.contributor.authorArita Claros, Luis Humberto
dc.contributor.authorLezameta Navarro, Rodrigo André
dc.date.accessioned2021-02-25T21:44:07Z
dc.date.available2021-02-25T21:44:07Z
dc.date.issued2021-01-15
dc.identifier.urihttp://hdl.handle.net/10757/654670
dc.description.abstractActualmente en la ciudad de Lima existe un número limitado de edificios de gran altura. Por lo que no existe mucha literatura de este tipo de edificaciones en Perú. Los códigos peruanos se enfocan en edificios de mediana y baja altura. Por ello, se requiere realizar estudios más detallados para analizar y diseñar de forma más adecuada estas edificaciones altas según la realidad del país. En el presente artículo, se desarrollará el análisis modal pushover a 6 tipos de edificaciones de concreto armado de 35 niveles en la ciudad de Lima. Se plantea 3 modelos de edificación con distinto sistema estructural y con diferentes plantas (cuadrada y rectangular), siendo las áreas de 29m x 29m y 52m x 26m respectivamente. Estos sistemas estructurales son de núcleo rígido y pórticos con sistema de disipación de energía (amortiguadores de fluido viscoso y disipadores SLB) con objetivo de estudiar su comportamiento frente a solicitaciones sísmicas. Estas edificaciones se establecieron en función de los criterios y requerimientos de los códigos vigentes en el país, como también, distribución de la planta de edificaciones comúnmente usadas para oficinas y viviendas. Se encontró que los periodos naturales oscilan entre 2.6 a 3.3 segundos para edificios de núcleo rígido, se presenta un incremento para los edificios de amortiguamiento viscoso de 4.2 a 5.4 segundos y también para los de dispositivos SLB oscilan en un rango de 3.7 a 4.6 segundos. Se realizó, a su vez, un análisis no lineal estático modal para obtener las curvas de capacidad para cada tipo de edificación, las cuales fueron comparadas con las demandas sísmicas según las provisiones de diseño de la norma peruana sísmica E.030 y un promedio de espectros de registros de aceleraciones de eventos sísmicos severos en Perú y escalados en un rango de 0.2T a 1.5T. Finalmente, se determinó los puntos de desempeño para cada caso de edificación siguiendo las metodologías del ATC-40 encontrando que los edificios altos con núcleo rígido presentan aproximadamente el doble de rigidez que los edificios con sistema de disipación de energía, como también, presentan poca ductilidad a diferencia con los edificios con disipadores que presentan una larga ductilidad.en_US
dc.description.abstractCurrently in Lima city there is a limited number of high-rise buildings. So, there isn’t much literature on this type of building in Peru. Peruvian codes focus on medium and low-rise buildings. Therefore, more detailed studies are required to analyze and design these tall buildings more appropriately according to the reality of the country. In this thesis, the modal pushover analysis of 6 types of 35-story reinforced concrete buildings in Lima city will be developed. Three building models with different structural system and with different plan (square and rectangular) are proposed, being their areas of 29m x 29m and 52m x 26m respectively. These structural systems are rigid core and frames with an energy dissipation system (viscous fluid dampers and SLB dissipators) in order to study their behavior against seismic stresses. These buildings were established based on the criteria and requirements of the current codes in the country, as well as, the distribution of the floors of buildings commonly used for offices and homes. Natural periods were found to range from 2.6 to 3.3 seconds for rigid core buildings, there is an increase for viscous damping buildings from 4.2 to 5.4 seconds and also for SLB devices to range from 3.7 to 4.6 seconds. In turn, a modal static nonlinear analysis was performed to obtain the capacity curves for each type of building, which were compared with the seismic demands according to the design provisions of the Peruvian seismic code E.030 and an average of spectra of acceleration records of severe seismic events in Peru and scaled in a range of 0.2T to 1.5T. Finally, the performance points for each building case were determined following the ATC-40 methodologies, finding that tall buildings with a rigid core have approximately twice the stiffness of buildings with an energy dissipation system, as well as having low ductility. unlike buildings with dissipators that have long ductility.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfen_US
dc.formatapplication/epuben_US
dc.formatapplication/msworden_US
dc.language.isospaen_US
dc.publisherUniversidad Peruana de Ciencias Aplicadas (UPC)en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.sourceUniversidad Peruana de Ciencias Aplicadas (UPC)es_PE
dc.sourceRepositorio Académico - UPCes_PE
dc.subjectVulnerabilidad sísmicaen_US
dc.subjectEdificios en alturaen_US
dc.subjectAnálisis modal pushoveren_US
dc.subjectNúcleo rígidoen_US
dc.subjectSeismic vulnerabilityen_US
dc.subjectTall buildingsen_US
dc.subjectModal pushover analysisen_US
dc.subjectRigid coreen_US
dc.titleComparación de la vulnerabilidad sísmica de edificios de concreto armado de 35 pisos con núcleo rígido, con amortiguadores de fluido viscoso y disipadores SLB, mediante el análisis modal pushover en la ciudad de Limaen_US
dc.title.alternativeComparison of the seismic vulnerability of 35-story reinforced concrete buildings with a rigid core, with viscous fluid dampers and SLB dissipators, using pushover modal analysis in Lima cityen_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.grantorUniversidad Peruana de Ciencias Aplicadas (UPC). Facultad de ingenieríaes_PE
thesis.degree.levelLicenciaturaes_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
refterms.dateFOA2021-03-16T21:44:05Z
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.00.00en_US
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01en_US
dc.identifier.isni0000 0001 2196 144X
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.advisor.orcidhttps://orcid.org/0000-0003-4697-6300en_US
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.discipline732016es_PE
dc.publisher.countryPEes_PE
dc.type.otherTesises_PE


Files in this item

Thumbnail
Name:
AritaC_C.pdf
Size:
11.87Mb
Format:
PDF
Thumbnail
Name:
AritaC_C.docx
Embargo:
2091-01-15
Size:
8.090Mb
Format:
Microsoft Word 2007
Thumbnail
Name:
AritaC_C_Ficha.pdf
Embargo:
2091-01-15
Size:
611.4Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess