Correlación entre la Auscultación Dinámica Ligera (DPL) y el Ensayo de Penetración Estándar (SPT) para suelos arenosos de origen aluvial ubicados en el distrito de Chilca, provincia de Cañete – departamento de Lima.
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Advisors
Durán Ramírez, Gary GaryIssue Date
2020-11-13
Metadata
Show full item recordOther Titles
Correlation of dynamic probing light (DPL) and standard penetration test (SPT) for sandy soil of alluvial origin located in the district of Chilca, province of Cañete, Department of LimaDOI
http://doi.org/10.19083/tesis/653611Abstract
En aplicaciones geotécnicas, el ensayo de penetración dinámica ligera (DPL) es un método alternativo a la Prueba de Penetración Estándar (SPT) para la determinación de los parámetros del suelo. La exigencia de diversas normativas para correlacionar ambos ensayos in situ y no establecer una metodología para realizarlo, limita el alcance práctico del DPL. La presente investigación desarrolla una metodología y una ecuación de correlación entre el ensayo de penetración dinámica ligera (DPL) y la Prueba de Penetración Estándar (SPT) específicamente para suelos arenosos (SP y SP-SM) ubicados en una zona del distrito de Chilca, provincia de Cañete, departamento de Lima. Para el análisis se utilizaron hasta 393 pares de datos, obteniendo correlaciones lineales entre el número de golpes obtenidos de la prueba de Penetración Estándar-NSPT y del ensayo de penetración dinámica ligera-N10; obteniendo un coeficiente de determinación (R2) entre 84% y 87%. La correlación obtenida se puede aplicar para obtener parámetros del suelo cuando el DPL se utiliza como complemento en investigaciones geotécnicas.In geotechnical applications, the dynamic probing light (DPL) is an alternative method to the Standard Penetration Test (SPT) for the determination of soil parameters. The requirement of various regulations for correlating both tests in the same field and not establishing a methodology to carry it out, limits the practical scope of dynamic probing light. This research presents a correlation methodology and the correlation between the dynamic probing light (DPL) and the Standard Penetration Test (SPT) specifically for sandy soils (SP and SP-SM) located in an area of Chilca, in Cañete - Lima - Peru. For the analysis, 393 data pairs were used, obtaining two linear correlations between the blow count of Standard Penetration-NSPT test and the dynamic probing light method-N10, which presented a coefficient of determination (R2) between 84% and 87 %. This correlation can be used to obtain soil parameters when the DPL is used in complementary geotechnical investigations.
Type
info:eu-repo/semantics/bachelorThesisRights
info:eu-repo/semantics/openAccessAttribution-NonCommercial-ShareAlike 4.0 International
Language
spaae974a485f413a2113503eed53cd6c53
http://doi.org/10.19083/tesis/653611
Scopus Count
Collections
The following license files are associated with this item:
- Creative Commons