Reforzamiento antisísmico en hospitales utilizando amortiguadores de fluido viscoso
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Issue Date
2019-10-16Keywords
Edificaciones esencialesDisipadores viscosos
Estructuras antisísmicas
Essential building
Viscous dissipaters
Metadata
Show full item recordCitation
[1] G. Cáceres Pérez and N. S. Pichihua Alata, “Reforzamiento antisísmico en hospitales utilizando amortiguadores de fluido viscoso,” Universidad Peruana de Ciencias Aplicadas (UPC), Lima, Perú, 2019. http://hdl.handle.net/10757/627651Abstract
En control antisísmico, se ha concluido que la adición de disipadores de fluido viscoso incrementa el amortiguamiento y controla los desplazamientos laterales de las estructuras, salvaguardándolas del posible colapso. El objetivo de este trabajo es comparar la respuesta de estructuras esenciales de albañilería confinada mayores a 50 años, con y sin amortiguadores viscosos. Adicionalmente, se analiza la estructura con una técnica de reforzamiento tradicional como son las placas de concreto armado, con el objetivo de evaluar la viabilidad de la primera propuesta. Los resultados indican que, con un reforzamiento con amortiguadores, las derivas se reducen de un 5.98%o a 3.33%o, y 4.42%o al implementar los muros de concreto armado, lo cual demuestra la viabilidad de la propuesta en respuestas estructurales.In seismic control, it has been concluded that the addition of viscous fluid dissipaters increases the damping and controls the lateral displacements of the structures, safeguarding them from possible collapse. The objective of this work is to compare the response of essential structures of confined masonry over 50 years, with and without viscous dampers. Additionally, the structure was analyzed with a traditional reinforcement technique such as reinforced concrete plates, with the objective of evaluating the viability of the first proposal. The results indicate that, with a reinforcement with shock absorbers, the drifts are reduced by 5.98%o or 3.33%o, or 4.42%o or by implementing the reinforced concrete walls, which demonstrates the viability of the proposal.
Type
info:eu-repo/semantics/bachelorThesisRights
info:eu-repo/semantics/openAccessAttribution-NonCommercial-ShareAlike 4.0 International
Language
spaCollections
The following license files are associated with this item:
- Creative Commons