Show simple item record

dc.contributor.advisorBarragán Salazar, Nathaly Carolina
dc.contributor.authorDávila Ramírez, Carolina Melky
dc.contributor.authorBarandiarán Calderón, Bruno
dc.date.accessioned2019-02-05T14:54:35Z
dc.date.available2019-02-05T14:54:35Z
dc.date.issued2018-11-07
dc.identifier.citation1. Dávila Ramírez CM, Barandiarán Calderón B. Comparación in vitro de la resistencia a la compresión de diferentes marcas de cemento ionómero de vidrio autocurable en la técnica de art [Internet]. [Lima, Perú]: Universidad Peruana de Ciencias Aplicadas(UPC).; 2018. Available from: http://hdl.handle.net/10757/625025es_PE
dc.identifier.doi10.19083/tesis/625025es_PE
dc.identifier.urihttp://hdl.handle.net/10757/625025
dc.description.abstractObjetivo: Comparar in vitro, la resistencia compresiva de cinco cementos ionómeros de vidrio: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), Maxxion R (FGM), y KetacTM Universal HM (3M ESPE); tras 24 horas, 7 y 60 días de mezclado. Materiales y métodos: Se seleccionaron tres cementos de ionómero de vidrio de alta viscosidad: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), y dos cementos de ionómero de vidrio convencionales: Maxxion R (FGM), KetacTM Universal HM (3M ESPE), indicados para el Tratamiento Restaurador Atraumático (TRA). La manipulación fue realizada en estricto cumplimiento con las indicaciones del fabricante. La unidad de análisis fue conformada por cilindros de ionómero de vidrio (2 mm de alto x 4 mm de diámetro), elaborados en una matriz metálica. Se crearon 15 especímenes por cada grupo de estudio, obteniendo un total de 225 especímenes. La prueba de resistencia a la compresión se dio mediante la máquina universal Instron® colocando los especímenes uno por uno verticalmente. La carga compresiva inicial tuvo una velocidad de 1mm/min hasta que la muestra se fracturase, y los resultados se registraron en megapascales (MPa). Resultados: El ionómero encapsulado GC EQUIATM Fil (Gc corporation) mostró mayores valores de resistencia compresiva a las 24 horas (299.80 MPa), mientras que a los 7 y 60 días fue el KetacTM Universal HM (3M ESPE), 77.04 MPa y 75.48 MPa, respectivamente. Por otro lado, existen diferencias significativas en la comparación de cada cemento de ionómero de vidrio en los tres tiempos de evaluación. Así como también, existen diferencias significativas en los tres tiempos evaluados: 24 horas: GC GC EQUIATM Fil (Gc corporation), a los 7 y 60 días KetacTM Universal HM (3M ESPE). Conclusión: El ionómero encapsulado GC EQUIATM Fil (Gc corporation) mostró mayores valores de resistencia compresiva a las 24 horas. Existen diferencias significativas en la comparación de cada cemento de ionómero de vidrio a lo largo de los tres tiempos, asimismo en cada tiempo de evaluación: 24 horas: GC EQUIATM Fil (Gc corporation), a los 7 y 60 días KetacTM Universal HM (3M ESPE). Objective: The aim of the present research was to compare in vitro the compressive strength of five glass ionomer cements: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), Maxxion R (FGM), and KetacTM Universal HM (3M ESPE); after 24 hours, 7 days and 60 days after the mixing process. Materials and methods: Three high-viscosity glass ionomer cements were selected for the present in vitro study: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), and also two conventional glass ionomer cements: Maxxion R (FGM), and KetacTM Universal HM (3M ESPE), recommended for the Atraumatic Restorative Treatment (ART). The mixing process was performed strictly respecting the manufacturer recommendations. The analysis unit was made of glass ionomer cylinders of 2mm high and 4mm in diameter, prepared with a metallic matrix. 15 samples were created for each study group, obtaining a total of 225 samples. The compressive strength was evaluated by Instron® universal machine placing the specimens one by one vertically, with a speed of 1mm / min until the sample fractured, and the results were registered in MPa. Results: The encapsulated ionomer GC EQUIATM Fil (Gc corporation) showed higher values of compressive strength at 24 hours (299.80 MPa), while at 7 and 60 days it was KetacTM Universal HM (3M ESPE), 77.04 MPa and 75.48 MPa, respectively. On the other hand, there are significant differences in the comparison of each glass ionomer cement in the three evaluation times. As well as, there are significant differences in the three times evaluated: 24 hours: GC EQUIATM Fil (Gc corporation), at 7 and 60 days KetacTM Universal HM (3M ESPE). Conclusion: The encapsulated ionomer GC EQUIATM Fil (Gc corporation) showed higher values of compressive strength at 24 hours. There are significant differences in the comparison of each glass ionomer cement over the three times, also at each evaluation time: 24 hours: GC EQUIATM Fil (Gc corporation), at 7 and 60 days KetacTM Universal HM (3M ESPE).en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfen_US
dc.formatapplication/epuben_US
dc.formatapplication/msworden_US
dc.language.isospaen_US
dc.publisherUniversidad Peruana de Ciencias Aplicadas (UPC)en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceUniversidad Peruana de Ciencias Aplicadas (UPC)es_PE
dc.sourceRepositorio Académico - UPCes_PE
dc.subjectCemento dentalen_US
dc.subjectOdontologíaen_US
dc.subjectRestauración dentalen_US
dc.subjectCemento dentarioen_US
dc.subjectReparación de dentaduraen_US
dc.titleComparación in vitro de la resistencia a la compresión de diferentes marcas de cemento ionómero de vidrio autocurable en la técnica de arten_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.grantorUniversidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ciencias de la Saludes_PE
thesis.degree.levelLicenciaturaes_PE
thesis.degree.disciplineOdontologíaes_PE
thesis.degree.nameCirujano dentistaes_PE
refterms.dateFOA2019-02-05T14:54:35Z
dc.identifier.isni0000 0001 2196 144X


Files in this item

Thumbnail
Name:
Barandiarán_ CB.pdf
Size:
476.9Kb
Format:
PDF
Thumbnail
Name:
Barandiarán_ CB.Ficha.pdf
Embargo:
2088-11-07
Size:
99.95Kb
Format:
PDF
Thumbnail
Name:
Barandiarán_ CB.docx
Embargo:
2088-11-07
Size:
335.9Kb
Format:
Microsoft Word 2007

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/embargoedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/embargoedAccess