Comparación in vitro de la resistencia a la compresión de diferentes marcas de cemento ionómero de vidrio autocurable en la técnica de art
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Advisors
Barragán Salazar, Nathaly CarolinaIssue Date
2018-11-07
Metadata
Show full item recordCitation
1. Dávila Ramírez CM, Barandiarán Calderón B. Comparación in vitro de la resistencia a la compresión de diferentes marcas de cemento ionómero de vidrio autocurable en la técnica de art [Internet]. [Lima, Perú]: Universidad Peruana de Ciencias Aplicadas(UPC).; 2018. Available from: http://hdl.handle.net/10757/625025DOI
10.19083/tesis/625025Abstract
Objetivo: Comparar in vitro, la resistencia compresiva de cinco cementos ionómeros de vidrio: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), Maxxion R (FGM), y KetacTM Universal HM (3M ESPE); tras 24 horas, 7 y 60 días de mezclado. Materiales y métodos: Se seleccionaron tres cementos de ionómero de vidrio de alta viscosidad: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), y dos cementos de ionómero de vidrio convencionales: Maxxion R (FGM), KetacTM Universal HM (3M ESPE), indicados para el Tratamiento Restaurador Atraumático (TRA). La manipulación fue realizada en estricto cumplimiento con las indicaciones del fabricante. La unidad de análisis fue conformada por cilindros de ionómero de vidrio (2 mm de alto x 4 mm de diámetro), elaborados en una matriz metálica. Se crearon 15 especímenes por cada grupo de estudio, obteniendo un total de 225 especímenes. La prueba de resistencia a la compresión se dio mediante la máquina universal Instron® colocando los especímenes uno por uno verticalmente. La carga compresiva inicial tuvo una velocidad de 1mm/min hasta que la muestra se fracturase, y los resultados se registraron en megapascales (MPa). Resultados: El ionómero encapsulado GC EQUIATM Fil (Gc corporation) mostró mayores valores de resistencia compresiva a las 24 horas (299.80 MPa), mientras que a los 7 y 60 días fue el KetacTM Universal HM (3M ESPE), 77.04 MPa y 75.48 MPa, respectivamente. Por otro lado, existen diferencias significativas en la comparación de cada cemento de ionómero de vidrio en los tres tiempos de evaluación. Así como también, existen diferencias significativas en los tres tiempos evaluados: 24 horas: GC GC EQUIATM Fil (Gc corporation), a los 7 y 60 días KetacTM Universal HM (3M ESPE). Conclusión: El ionómero encapsulado GC EQUIATM Fil (Gc corporation) mostró mayores valores de resistencia compresiva a las 24 horas. Existen diferencias significativas en la comparación de cada cemento de ionómero de vidrio a lo largo de los tres tiempos, asimismo en cada tiempo de evaluación: 24 horas: GC EQUIATM Fil (Gc corporation), a los 7 y 60 días KetacTM Universal HM (3M ESPE). Objective: The aim of the present research was to compare in vitro the compressive strength of five glass ionomer cements: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), Maxxion R (FGM), and KetacTM Universal HM (3M ESPE); after 24 hours, 7 days and 60 days after the mixing process. Materials and methods: Three high-viscosity glass ionomer cements were selected for the present in vitro study: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), and also two conventional glass ionomer cements: Maxxion R (FGM), and KetacTM Universal HM (3M ESPE), recommended for the Atraumatic Restorative Treatment (ART). The mixing process was performed strictly respecting the manufacturer recommendations. The analysis unit was made of glass ionomer cylinders of 2mm high and 4mm in diameter, prepared with a metallic matrix. 15 samples were created for each study group, obtaining a total of 225 samples. The compressive strength was evaluated by Instron® universal machine placing the specimens one by one vertically, with a speed of 1mm / min until the sample fractured, and the results were registered in MPa. Results: The encapsulated ionomer GC EQUIATM Fil (Gc corporation) showed higher values of compressive strength at 24 hours (299.80 MPa), while at 7 and 60 days it was KetacTM Universal HM (3M ESPE), 77.04 MPa and 75.48 MPa, respectively. On the other hand, there are significant differences in the comparison of each glass ionomer cement in the three evaluation times. As well as, there are significant differences in the three times evaluated: 24 hours: GC EQUIATM Fil (Gc corporation), at 7 and 60 days KetacTM Universal HM (3M ESPE). Conclusion: The encapsulated ionomer GC EQUIATM Fil (Gc corporation) showed higher values of compressive strength at 24 hours. There are significant differences in the comparison of each glass ionomer cement over the three times, also at each evaluation time: 24 hours: GC EQUIATM Fil (Gc corporation), at 7 and 60 days KetacTM Universal HM (3M ESPE).Type
info:eu-repo/semantics/bachelorThesisRights
info:eu-repo/semantics/embargoedAccessAttribution-NonCommercial-ShareAlike 3.0 United States
Language
spaae974a485f413a2113503eed53cd6c53
10.19083/tesis/625025
Scopus Count
Collections
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/embargoedAccess