• Comparación de dos técnicas no farmacológicas en el control de la ansiedad en niños antes, durante y después del tratamiento dental

      Ramírez, María Cecilia; Reyes Bossio, Mario; Alarco Cadillo, Lorena (Universidad Peruana de Ciencias Aplicadas (UPC), 2017-04-04)
      Nowadays you can opt for non-pharmacological techniques for the control and management of anxiety problems as it significantly influences the behavior of children during dental consultation and negatively affects their oral health and a high level of anxiety produces a total rejection of child dental care. Objective: To compare two non-pharmacological techniques (music therapy and audiovisual distraction) in controlling anxiety before, during and after dental treatment of children between 5 and 10 years old attended at the University Health Center of the Universidad Peruana de Ciencias Aplicadas. Materials and Methods: a quasi-experimental study was conducted and anxiety levels obtained with Venham Picture Test and Venham Anxiety Scale a total of 60 pediatric patients under non-pharmacological techniques music therapy and audiovisual distraction was compared. Results: The mean score obtained before the dental consultation with the Venham Picture Test for the control group was 2, for the music therapy group was 1.4 and 1.45 for the audiovisual group; the mean score obtained during the dental consultation with the Venham Anxiety Scale for the control group was 1.4 , for the music therapy group was 0.2 and 0.2 for the audiovisual group; the average after dental consultation for the control group was 1.95, for music therapy was 0.45 and the audiovisual group was 0.3. Conclusions: The results indicate that if there was a reduction in anxiety levels by using both non-pharmacological techniques in the study population.
      Acceso restringido temporalmente
    • Comparación de la dimensión del espacio aéreo faringeo según las deformidades esqueleticas clase I, II y III en radiografías cefalométricas de pacientes que asistieron a la clínica docente UPC entre los años 2011 al 2014

      Ghersi Miranda, Hugo; Mendoza Lugo, Julián Alejando (Universidad Peruana de Ciencias Aplicadas (UPC), 2017-03-27)
      Objetives: Compare the dimension of the pharyngeal airspace according to the skeletal deformities class I, II and III in cephalometric radiographs. Materials and methods: A descriptive and retrospective type of study was made where there were analyzed 106 side radiographies, taken in the X-ray center of the University health Center of the Peruvian University of Applied Sciences UPC between the years 2011 and 2014. Through the program Nemotec ® the main cephalometrics points and tracings were marked to be able to obtain the skeletal deformity (Steiner) and the dimension of the upper and lower airspace (McNamara). Resultados: In the upper pharyngeal airspace it was found that the highest average dimension was 17.68 mm founded in the skeletal deformation class III, and the lowest in class II with a value of 13.71 mm. Fort the lower airspace, the highest average was 15.98mm and the lowest 13.19mm, also founded in skeletal deformation Class III and Class II respectively. While comparing the size of the pharyngeal space between classes of deformity, it was found that there is statistically significant difference between the upper airspace of skeletal deformities class II and III with a value of p = 0.001; and in the lower, between classes III - I and III - II with values of p=0.0236 and p=0.0042 respectively. Conclusions: In this study it was found that there is a statistically significant difference in the pharingeal airspace between class II and III skeletal deformities.
      Acceso abierto
    • Comparación de la distorsión geométrica lineal de la telerradiografía digital con la telerradiografía convencional en cráneos humanos

      Morzán Valderrama, Eduardo; Grández Molina, Madeleine Alessandra (Universidad Peruana de Ciencias Aplicadas (UPC), 04/07/2014)
      La telerradiografía lateral es una herramienta esencial en la práctica clínica especialmente en el área de ortodoncia, nos permite realizar mediciones para investigar el desarrollo y crecimiento del esqueleto facial, ayudando en el diagnóstico y plan de tratamiento de cada paciente. El primer tipo de radiografía utilizada fueron las convencionales y con el desarrollo de la tecnología, fue evolucionando hasta ser digital. El propósito de este estudio fue comparar la distorsión geométrica de la telerradiografía lateral digital con la telerradiografía convencional en cráneos de cadáveres humanos. La muestra fue tomada por conveniencia, siendo conformada por 21 cráneos secos de cadáveres humanos, se le colocaron tres marcadores de plomo a cada cráneo. El primer marcador estuvo a nivel de la unión de las suturas esfenofrontal ,coronal, escamosa y esfenoescamosa y paralelo al plano de Frankfort. El segundo debajo de la sutura frontocigomática y el último a nivel de la rama de la mandíbula y posicionado en la parte más cóncava de la línea anterior y paralela al plano de Frankfort. No se hallaron diferencias significativas al comparar las medidas de las placas convencionales y digitales en el tercio medio y superior, pero al analizar el tercer tercio si se hallaron diferencias entre las imágenes convencionales y digitales. En cuanto a la comparación con el gold standard, todas las placas presentaron distorsión. PALABRAS CLAVES: telerradiografía lateral, distorsión, telerradiografía convencional, telerradiografía digital
      Acceso abierto
    • Comparación de la percepción de estética facial en perfiles entre alumnos, odontólogos y pacientes

      Salinas Caldas, Pedro; Caballero García, Stefany; Arce Silva, Huberto Gonzalo (Universidad Peruana de Ciencias Aplicadas (UPC), 2018-03-01)
      Objective: To compare the perception of facial aesthetics in patients, among students, patients and teachers of the UPC health center. Materials and Methods: A panel of 45 dentist, 45 dental students and 45 patients evaluated the facial aesthetics in the profile of 12 patients (3 patients for each malocclusion) using a visual analog scale (VAS) rating from 0 to 10 (from less to more attractive). Results: The results showed that for the three groups studied the most aesthetic malocclusion was the class II division 2. In addition. It was demonstrated that the student group was the strictest group and the one that rated profiles more negatively. Conclusions: The study supports the idea that the perception of aesthetic varies according to different populations. The results show class II division 2 malocclusion as the most aesthetic which differs to similar studies performed in foreign populations.
      Acceso abierto
    • Comparación de la resistencia a la compresión de un cemento experimental con el óxido de zinc y Eugenol, Coltosol® F, Ketac™ Molar y Clip F

      Gonzales Soto, Néstor; Reyes Galindo, Carmen Maritza; Moscoso Huamaní, Melissa Alexandra (Universidad Peruana de Ciencias Aplicadas (UPC), 2018-12-31)
      Objective: Compare the compressive strength of the experimental cement with Zinc Oxide and Eugenol, Coltosol ® F, Ketac™ Molar Easymix 3M (ESPE) and Clip F (VOCO). Materials and Methods: This study was of experimental type in vitro. The analysis unit consisted of a cylinder-shaped specimen with the different temporary restoration materials. The sample had 10 groups of 11 specimens each, distributed according to the type of material and the measurement times, with uniform measurements of 6mm in diameter and 4mm in height. Then, these samples were immersed in distilled water until their respective measurement. After that, the compressive strength was evaluated on the Instron® machine at a speed of 1mm/ 1min. Finally, the data was analyzed using the Kruskall Wallis test. Results: In this study, the experimental cement obtained higher values of compressive strength (10.78+0.77 MPa in the 7th day) and (2.94 ± 1.03 MPa in the 14th day) in comparison of Coltosol® F (7.87+0.61MPa) and (2.72 ± 0.32MPa); and Zinc Oxide and Eugenol (6.22+0.78 MPa) and (1.64 ± 0.50MPa). That means that statistically significant differences between all temporary restoration materials were found. Conclusions: Between the days 7 and 14, the compressive strength of the experimental cement was higher than the Zinc Oxide and Eugenol and Coltosol® F materials. However, the highest values of resistance were for the Ketac™ Molar Easymix 3M (ESPE) and Clip F (VOCO) groups.
      Acceso abierto
    • Comparación de la resistencia compresiva de resinas convencionales vs resinas tipo bulk fill

      Cafferata Montoya, Paola; Casas Apayco, Leslie; Falcón Cabrera, Giancarlo; Acurio Benavente, Paloma (Universidad Peruana de Ciencias Aplicadas (UPC), 22/02/2017)
      Objective: The aim of this study was compare the compressive strength of 2 Bulk fill resin composites and 2 conventional resin composites. Materials and methods: one hundred and thirty six cylindrical samples (2mm and 4mm), divided in 8 groups (n = 17); G1 SonicFill™ (4x2mm), G2 SonicFill™ (4x4mm), G3 Tetric® N-Ceram Bulk Fill (4x2mm), G4 Tetric® N-Ceram Bulk Fill (4x4mm), G5 Filtek™ Z250 XT (4x2mm), G6 Filtek™ Z250 XT (4x4mm), G7 Te-Econom Plus® (4x2mm) and G8 Te-Econom Plus® (4x4mm). Specimens were evaluated to compressive stress test using Instron® machine at crosshead speed of 1.0 mm/min. One way Anova, Kruskall Wallis, Student's t and U Mann Whitney tests were employed for statistical analyses. Results: For Bulk resin composites, Tetric® N-Ceram Bulk Fill (310.06-4x2mm, 303.87-4x4mm) showed higher compressive strength than SonicFill™. For conventional resin composites, Filtek™ Z250 XT (295.9-4x2mm, 289.7-4x4mm) showed higher compressive strength than Te-Econom Plus®. For comparison,Tetric® N-Ceram Bulk Fill was higher compressive strength in both thickness 4x2mm (p=0.122) and 4x4mm (p=0.333) and it was statistically significant (<0.001*-4x2mm, 0.004-4x4mm) among them. Conclusion: Tetric® N-Ceram Bulk Fill offers a good mechanical property like a compressive strength which is better in comparison to the others resin composites evaluated in this study.
      Acceso restringido temporalmente
    • Comparación de la sensibilidad durante y después del blanqueamiento domiciliario con peróxido de carbamida al 10% y 16 % en pacientes de una clínica docente odontológica

      Cafferata Montoya, Paola Antonella; Pella Ato, Arabella (Universidad Peruana de Ciencias Aplicadas (UPC), 2017-01-30)
      Objective: To compare the dentin sensitivity during and after home whitening with 10% and 16% carbamide peroxide in patients of the Teaching Dental Clinic of the Peruvian University of Applied Sciences, UPC (2015-2). Materials and Methods: : 44 patients were received, under standardized conditions, home whitening with 10% and 16% carbamide peroxide and were randomly divided in 2 groups according to the concentration of carbamide peroxide. Tooth sensitivity was measured according to the Visual Analogue Scale (VAS) at 1, 7, 14 and 21 days. Tooth sensitivity generated by both concentrations of carbamide peroxide was compared with the Kruskal Wallis test. Results: The group using 16% carbamide peroxide had higher average score sensitivity (EVA) on day 1 (1.59 + 1.95), day 7 (1.88 + 1.48), day 14 (1.26 + 1.16) and day 21 (0.05 + 0.13), while the group with 10% carbamide peroxide had the following scores: Day 1 (0.8 + 0.83), day 7 (1.24 + 0.97), day 14 (0.55 + 0.62) and day 21 (0.01 + 0.64). Conclusions: Statistically significant differences observed when comparing the 10% and 16% carbamide peroxide, with the 16% carbamide peroxide generating more sensitivity in all patients.
      Acceso abierto
    • Comparación de los factores de riesgo de caries dental en escolares de 6 a 12 años de una institución educativa pública con una privada en el 2014

      Flores Barrantes, Lorena; Solís Rosado, Maribel Jhaneth (Universidad Peruana de Ciencias Aplicadas (UPC), 11/03/2016)
      Objective: The goal is to compare dental caries risk factors among six to twelve-year-old students from a public school and a private school in 2014. Materials and Methods: This study was observational, descriptive, transverse and prospective. The study was conducted with 173 students from a public school and 168 students from a private school, from the ages of 6- to 12 year, both males and females. Which assessed, compared and associated the existence of dental caries, decayed, missing and filled teeth index DMFT and dmts, oral hygiene index (OHI), body mass index (BMI), and saliva PH level on a cluster sample of students from both schools. Results: Dental caries among public school population was 94.80%, DMFT 1.38 +1 and dmts 6-23+6 while the private school population results revealed a 72.02%, DMFT 1.08+0 and dmts 3.98 +2. No significant differences between the BMI and saliva PH level and their relation with dental caries were found. However, a significantly connection between dental caries and OHI was revealed after comparing the DMFT and dmts from both institutions (p=0.014) and (p=0.000). Conclusion: This study’s findings support the statement that economics status of both educational institutions has influence on the prevalence of dental caries among their students. Research has shown that BMI and saliva PH level are not dental caries prevalent factors. However, OHI has a close association with the presence of dental caries within both schools.
      Acceso abierto
    • Comparación de los métodos de Demirjian y Nolla para la estimación de la edad dental en niños de 6-15 años atendidos en la clínica docente UPC

      Campos Campos, Katherine Jeanette; Aguirre Gonzales, Karla Katherine (Universidad Peruana de Ciencias Aplicadas (UPC), 04/12/2015)
      Objetivo: comparar los métodos de Demirjian y Nolla para la estimación de la edad cronológica en niños de 6-15 años que se atienden en la Clínica Docente de la Universidad Peruana de Ciencias Aplicadas (UPC). Materiales y Métodos: el estudio retrospectivo se realizó en las radiografías panorámicas de 300 sujetos en edades comprendidas de 6-15 años. La edad media dental (ED) de acuerdo a los métodos Demirjian y Nolla se compararon con la media de la edad cronológica (EC). Para ello, se utilizó la prueba de rangos de Wilcoxon. Resultados: la EC media de la muestra fue de 9.38±2.09 y 9.38±2.09 años para las mujeres y los hombres, respectivamente. Utilizando el método de Demirjian, la media estimada de la ED fue de 10.19±2.61 años para las mujeres y 10.23±2.49 años para los hombres. Para el método de Nolla, la media estimada de la ED fue de 8.65±2.61 y 9.03±2.37 años para las mujeres y hombres, respectivamente. Las diferencias de medias entre la ED y EC de acuerdo con los métodos Demirjian y Nolla fueron de 0,82 y -0,52 años para la muestra total del estudio. Conclusiones: se encontró diferencias estadísticamente significativas en ambos métodos. El método de Demirjian sobrestimó a la edad cronológica y Nolla subestimó a la edad cronológica.
      Acceso abierto
    • Comparación del adiestramiento manual para la preparación cavitaria clase II para resina compuesta según la metodología tradicional vs el uso de una metodología innovadora en los alumnos de Pre-grado de la Escuela de Odontología de la Universidad Peruana de Ciencias Aplicadas en el periodo 2013-1

      Hermoza Novoa, Mónica; Ticona Huamaní, Lovely Carmela (Universidad Peruana de Ciencias Aplicadas (UPC), 30/06/2014)
      Introducción: La simulación clínica está considerada como una estrategia de enseñanza que permite prevenir y evaluar riesgos que pueden generarse durante las actividades clínicas. Se ha observado cambios sustanciales en los diferentes instrumentos de simulación a través de los años, sin embargo pocas universidades peruanas han adoptado el uso de nuevas tecnologías. Objetivo: Evaluar el adiestramiento manual del alumno en la preparación de cavidades clase II, comparando los instrumentos de enseñanza utilizados por alumnos de pre grado de la UPC: tipodont y fantomas. Así mismo, evaluar la percepción del alumno después del uso de los instrumentos de simulación propuestos. Materiales y Métodos: Se realizó un estudio cuasi-experimental con 36 alumnos de pre grado de la universidad Peruana de Ciencias Aplicadas que no presentaban ningún tipo de experiencia previa en preparaciones cavitarias. Los alumnos fueron divididos en dos grupos de 18 cada uno. Al primer grupo que trabajó con tipodont se le denominó (M1); y al segundo grupo que trabajó con fantomas se le denominó (M2). Ambos grupos realizaron preparaciones en dos sesiones: una inicial o A donde el alumno tuvo el primer contacto con el simulador (tipodont o fantoma) y una final o B donde el alumno demostraba sus habilidades adquiridas en un fantoma. De esta manera, los grupos se dividieron en Grupos M1A, M1B, M2A, M2B. Todas las cavidades fueron evaluadas por un solo examinador especialista en el área de Odontología Restauradora que no tenía conocimiento de los grupos. El examinador evaluó el nivel de adiestramiento manual de los alumnos, utilizando un microscopio operatorio Global® para evaluar la calidad del margen gingival, y un vernier digital para medir la conformación de las preparaciones cavitarias. La percepción de los alumnos fue evaluada a través de sus componentes: operatividad y confort, para las cuales se utilizaron dos encuestas validadas por Quinn (20) y Mendoza (4), las cuales fueron integradas en una sola encuesta (anexo 2). Las encuestas se realizaron sólo para el grupo “M1”; al final del momento inicial y final. Resultados: Con respecto al adiestramiento manual. Los resultados muestran para el grupo “M1A” una calidad aceptable del margen gingival del 16.67% en comparación al grupo M2A que tuvo 5.56% en su primera experiencia en simulación con fantomas. Sin embargo para un tiempo “B”, M1B obtuvo un valor de margen aceptable de 16.67% mientras que el grupo M2B lo superó en un 33.33%. Para la conformación de las preparaciones cavitarias para muestras independientes (p<0.05) no se encontraron diferencias estadísticamente significativas en ambos grupos para ambos tiempos, “A” y “B”. Sólo se encontró diferencias estadísticamente significativas para el istmo de la caja oclusal en ambos grupos y tiempos. Con respecto a la percepción de los alumnos, los resultados muestran que la operatividad del grupo M1 considera un nivel de exigencia del uso del tipodont en el momento inicial de 16.67% en comparación a su percepción en el momento final que valora la exigencia del tipodont en un 3.13%, y la exigencia del fantoma en un 26.47%. Para evaluar el confort de los alumnos, en la pregunta: “Me pareció estar frente a un paciente real”, el 28% del grupo M1 en el momento inicial estuvo fuertemente de acuerdo; mientras que ningún miembro del grupo M1 que calificó el tipodont en el momento final respondió estar fuertemente de acuerdo, pero que para el grupo M1B2 consideró que si lo estaba en un 94%. Conclusión: Los resultados del estudio demostraron que el uso del instrumento de simulación utilizando fantomas, permite un mejor adiestramiento para la realización de preparaciones clase II en la calidad del margen gingival y la conformación de las preparaciones en un momento final y es más valorado por los alumnos según su percepción; sin embargo la práctica utilizando tipodont en un momento final también genera buenos resultados pero no logra superar al uso del fantoma.
      Acceso abierto
    • Comparación del ángulo de convergencia en dientes preparados para coronas según la clínica cursada por estudiantes de odontología de la Universidad Peruana de Ciencias Aplicadas (UPC)

      Revoredo de Rojas, Arturo; Guevara Álvarez, Maricarmen (Universidad Peruana de Ciencias Aplicadas (UPC), 06/03/2016)
      The aim of this study was to compare the convergence angle in teeth prepared for crowns for students of School of Dentistry Peruvian University of Applied Sciences (UPC). 76 students in 7th to 10th cycle prepared 152 dental pieces between incisors and premolars, to receive a ceramic metal crown. The images of the vestibulolingual (VL) and mesiodistal (MD) faces of the prepared teeth were measured and the AC of said faces was measured with the aid of AutoCAD software (Autodesk). A significant difference (p = 0.003) was found in part 21 on the VL face, due to the position of the piece in the oral cavity, indirect vision and operator ability. The highest average AC in piece 21 was in the face VL and MD with 25.27 º + 8.47 and 15.81 º + 4.23 respectively. On the other hand, for piece 24 in the VL and MD was 14.83 º and 17.45 º respectively. There was no great difference between the AC of the other carved pieces.
      Acceso abierto
    • Comparación del control de higiene oral posterior a la aplicación de un material educativo físico versus material educativo multimedia en los alumnos de una institución educativa primaria pública del distrito de Chilca

      Pérez Vega, Estefany; Ceccarelli Calle, Juan Francisco; Pérez Vega, Estefany (Universidad Peruana de Ciencias Aplicadas (UPC), 18/11/2015)
      Objetivo: comparar el control de higiene oral posterior a la aplicación de un material educativo físico con un material educativo multimedia en los alumnos de una institución primaria pública del distrito de Chilca. Materiales y métodos: se realizó un estudio cuasi-experimental con una muestra de 58 alumnos entre 9 y 12 años de edad en una institución educativa de Chilca. Se utilizó dos materiales educativos, uno físico y el otro multimedia y fueron validados por una ONG. Los participantes se dividieron en dos grupos: al primero se le aplicó material educativo físico y al segundo material multimedia; ambas sesiones educativas duraron 30 minutos. Se registró el índice de placa blanda según O´Leary en el tiempo inicial, a los 15 días y al mes. Resultados: en el material educativo físico, el promedio del porcentaje del índice de placa blanda al segundo control que se realizó al mes, obtuvo una media de 5.97% + 5.52 y la del material educativo multimedia fue de 3.73% + 4.08; la comparación de estas medias no presentaron diferencias estadísticamente significativas (p< 0.05). Sin embargo, al comparar los promedios del porcentaje obtenidos a los 15 días para ambos materiales educativos, material educativo físico 20.76% +15.05 y en el material educativo multimedia 12.72% +8.82, presentan diferencias estadísticamente significativas, y se observa que el p valor fue de 0.03 (p < 0.05). Conclusiones: al comparar el control de higiene oral posterior a la aplicación del material educativo físico versus material educativo multimedia no se encontraron diferencias estadísticamente significativas al mes de evaluación, sin embargo a los 15 días de evaluación sí se hallaron diferencias estadísticamente significativas, favoreciendo en los resultados al material educativo multimedia. Ambas herramientas educativas actuaron por igual y ayudaron a disminuir progresivamente el índice de placa blanda de los alumnos evaluados.
      Acceso abierto
    • Comparación del efecto in vitro de la microdureza en la superficie del Esmalte en bloques de dientes de bovino tratadas con Mi Varnishtm (Fluoruro de Sodio al 5%) y Duraphat® (Fluoruro de Sodio al 5%).

      Flores Barrantes, Lorena; Casas Apayco , Leslie; Gómez Zegarra, Cossette Susana (Universidad Peruana de Ciencias Aplicadas (UPC), 01/12/2015)
      Objective: The objective of the study was to compare in vitro the microhardness on the enamel surface in blocks of bovine central incisors treated with My VarnishTM (sodium fluoride 5%) and Duraphat® (Sodium fluoride 5%). Materials and Methods: This was an experimental in vitro study divided in three groups: (1) Control-Artificial saliva; (2) Duraphat® (Sodium fluoride 5%); (3) Mi VarnishTM (sodium fluoride 5% and CPP-ACP). Each group was submitted to a pre-cariogenic challenge during 7 days in vitro cycles pH model proposed by Cate and Duijsters. After the formation of the in vitro white spot lesion they were analyzed using microhardness Vickers method. Finally, the specimens were remineralized using fluoride varnishes Mi VarnishTM and Duraphat® and to monitor and compare the microhardness they were measured every 48 hours, 7 days and 14 days. Results: The results in Control group were in Baseline 52.03 ± 25.52, 48 hours 60.95 ± 21.77, 7 days 65.53 ± 21.78 and 14 days 61.04, ± 21.23. Then My VarnishTM: Baseline 54.85, ± 28.3, 48 hours 70.47, ± 27.03, 7 days 75.44, ± 22.92 and 14 days 71.74, ± 24.56. Finally in Duraphat®: Baseline 54.63 ± 45.46, 69.19 ± 48.32, 73.69 ± 25.98, 70.97 ± 43.18 as baseline, at 48 hours, 7 days and 14 days respectively. Conclusions: Mi VarnishTM and Duraphat® have no statistically significant differences.
      Acceso abierto
    • Comparación del índice de higiene oral posterior a la aplicación de la técnica visual de retroalimentación y convencional en niños de 6 a 9 años de un centro educativo público en el distrito de Ate – Vitarte en el año 2013

      Ceccarelli Calle, Juan Francisco; Flores Ventocilla, Kathleen Mayte (Universidad Peruana de Ciencias Aplicadas (UPC), 05/12/2014)
      Objetivo: Comparar el índice de higiene oral posterior a la aplicación de la técnica visual de retroalimentación y convencional en niños de 6 a 9 años en un centro educativo público del distrito de Ate-Vitarte en el año 2013. Materiales y métodos: Se realizó un diseño de estudio de tipo cuasiexperimental, para lo cual se evaluó a un total de 59 niños en edades comprendidas entre 6 y 9, siendo 33 mujeres y 26 hombres. Los participantes fueron distribuidos en dos grupos, al grupo A se le entregó pastillas reveladoras de placa bacteriana para usarlas en casa durante las noches por un total de 28 días y el grupo B constituyó el control, al cual no se les proporcionó las pastillas reveladoras. Se le entregó en la primera cita una pastilla revaladora de placa bacteriana a la totalidad de participantes del grupo A y B, la cual debía ser utilizada en la primera sesión. Sólo el grupo A con la ayuda de un espejo facial verificó las zonas en la cual su cepillado fue deficiente. Se realizó la instrucción de higiene oral a todos los participantes de ambos con ayuda de material multimedia en la cual se explicaba sobre la caries dental, enfermedad periodontal y la técnica de cepillado según Bass. Se utilizó el índice de higiene oral de Green y Vermillion y se registró en la ficha de recolección de datos. Posteriormente, se procedió a obsequiarles un cepillo y pasta dental, la cual fue utilizada para remover la placa bacteriana blanda y en algunos participantes se utilizó instrumentos manuales para retirar la placa bacteriana calcificada. Se evaluó el índice de higiene oral a los 7 y 28 días. No hubo diferencias estadísticamente significativas entre el uso de la técnica visual de retroalimentación y la técnica convencional. Asimismo, no se encontró asociación entre la edad y género respecto a las técnicas. Conclusiones: Ambas técnicas disminuyen el índice de higiene oral de igual manera en niños con edades comprendidas entre 6 y 9 años. Asimismo, no se encontró asociación entre la edad y el género.
      Acceso abierto
    • Comparación in vitro de la microdureza superficial de la resina compuesta Tetric® N-Ceram Bulk Fill y Sonicfill™ según profundidad de fotocurado

      Hermoza Novoa, Mónica; Rapizza Alvarez, Jael Antonella (Universidad Peruana de Ciencias Aplicadas (UPC), 19/11/2015)
      Objetivo: comparar in vitro la microdureza superficial de la resina Tetric® N-Ceram Bulk Fill y la resina SonicFill™, según profundidad de fotocurado. Materiales y métodos: el estudio fue experimental in vitro. Se realizaron 32 cuerpos de prueba divididos en 4 grupos: Tetric® N-Ceram Bulk Fill a 2mm de espesor, Tetric® N-Ceram Bulk Fill a 4mm de espesor, SonicFill™ a 2mm de espesor, SonicFill™ a 4mm de espesor. Se prepararon en matrices metálicas de 6x2x4 mm de espesor, los cuales fueron irradiados desde la superficie más superficial. Todos los especímenes se almacenaron en una estufa a 37◦C durante 24 horas, antes de la medición. La dureza Vickers se midió en función al espesor del material por la superficie superior e inferior del cuerpo de prueba, de los cuatro grupos antes mencionados. Los datos se analizaron con las pruebas de Shapiro Wilk y t de Student. Resultados: la resina SonicFill™ a los 2 y 4mm de espesor tuvo mayor microdureza superficial con una media de74.75+3.38kg/mm2 y 72.65+1.93kg/mm2 respectivamente a comparación de la resina Tetric® N-Ceram Bulk Fill. Por otro lado la microdureza superficial de la resina Tetric® N-Ceram Bulk Fill y SonicFill™en la superficie superior es mayor con una media de 60.87+2.53kg/mm2 y 74.75+3.38kg/mm2 que en la superficie inferior con una media de 51.25+1.95kg/mm2 y 71.37+2.68 kg/mm2. Conclusiones: se encontraron diferencias estadísticamente significativas al comparar las resinas Tetric® N-Ceram Bulk Fill y SonicFill™ a los 2mm y 4mm de profundidad, con mayor microdureza superficial en la resina SonicFill™a los 2mm y 4mm de profundidad en la superficie superior.
      Acceso restringido temporalmente
    • Comparación in vitro de la actividad antibacteriana de tres ionómeros de restauración sobre cultivos de streptococcus mutans (ATCC 25175) y streptococcus sanguinis (ATCC10556)

      Flores Barrantes, Lorena; Yovera Vargas, July; León Ríos, Ximena Alejandra (Universidad Peruana de Ciencias Aplicadas (UPC), 19/11/2015)
      Introducción: la actividad antibacteriana de los materiales de restauración tiene un papel importante en la prevención de caries recidivante. Objetivos: comparar la actividad antibacteriana de tres ionómeros de vidrio Ketac Molar®, Fuji II LC® y Maxxion R® contra cepas Streptococcus mutans (ATCC 25175) y Streptococcus sanguinis Materiales y métodos: el estudio fue experimental in vitro y consistió en la evaluación de la actividad antibacteriana de tres ionómeros de vidrio: Ketac Molar®, Fuji II LC® y Maxxion R®, los cuáles fueron preparados en cumplimiento de las recomendaciones del fabricante y se insertaron en pozos confeccionados con puntas desechables estériles utilizando el sistema Centrix® en placas de petri con agar BHI. Por otro lado, la actividad antibacteriana se evaluó mediante el uso de un vernier para medir el diámetro de los halos de inhibición del crecimiento de las cepas ensayadas; asimismo, se evaluó la supervivencia y proliferación de las bacterias sobre los ionómeros mediante el método de la reducción de 3-(4,5-Dimetiltiazol-2-yl)-2,5-difenil tetrazolio bromuro (MTT).En cuanto al análisis de la viabilidad del Streptococcus mutans fue de 1.221nm para el Ketac Molar®, 0.457nm para el Maxxion R® y 0.804nm para el Fuji II®. Asimismo, la viabilidad del Streptococcus sanguinis fue de 0.3175nm para el Ketac Molar®, 1.195nm para el Maxxion R® y 0.276nm para el Fuji II®. El estudio se realizó por triplicado y el análisis estadístico utilizó la prueba de ANOVA a 3 criterios. Resultados: el Ketac Molar®, Fuji II® y Maxxion R® mostraron halos de inhibición de 16.27mm ± 1.62, 11.95 mm ± 1.51 y 12.38 mm ±2.55 contra cepas de Streptococcus mutans respectivamente con un p= 0.0001, lo que significa que existe diferencia estadísticamente significativa. Asimismo, se encontraron halos de inhibición del Ketac Molar®, Fuji II® y Maxxion R® contra cepas de Streptococcus sanguinis de 10.11mm ±1.42, 13.51mm ±2.34 y 10.83m m ±1.22 respectivamente con un p= 0.0008, lo que demuestra que también existe diferencia significativa. Conclusión: los tres cementos de ionómero de vidrios evaluados, presentaron halos de inhibición del crecimiento de las bacterias cariogénicas ensayadas. Sin embargo, el Ketac Molar® tuvo mayor actividad antibacteriana contra el Streptococcus mutans ; mientras que el Fuji II® tuvo mayor actividad antibacteriana contra el Streptococcus sanguinis.
      Acceso restringido temporalmente
    • Comparación in vitro de la alteración dimensional del modelo definitivo según el tiempo de vaciado de la silicona por condensación

      Pagán Yábar, Luis Antonio; Ramírez Necochea, Dreyci Mildred (Universidad Peruana de Ciencias Aplicadas (UPC), 01/12/2014)
      Objetivo: Comparar in vitro la alteración dimensional de los modelos definitivos obtenidos con la silicona por condensación marca Zhermack® tipo Zetaplus Oranwash, según 3 tiempos de vaciado en base al modelo maestro. Materiales y métodos: Se tomaron 36 impresiones a un modelo maestro de acero inoxidable con la silicona por condensación Zhermack® y se dividieron en 3 grupos según el tiempo de vaciado (0, 0.5 y 72 horas). Para determinar la alteración dimensional de los modelos definitivos en comparación al modelo maestro, se midieron 8 localizaciones con una máquina especializada en coordenadas, modelo Contura G2 con tecnología de Scanning por contacto ZEISS. Resultados: Para el estudio se realizó la prueba no paramétrica de Wilcoxon. Sólo presentaron diferencias estadísticamente significativas 6 de las 8 localizaciones: A, C, D, E, F y G; siendo mayor la alteración dimensional en los modelos definitivos vaciados a las 0 y 72 horas. Se debe tomar en cuenta que, el no encontrar resultados estadísticamente significativos en 2 de las 8 localizaciones puede deberse a que cada localización es independiente una de otra, cada una con valores diferentes como se aprecia en el modelo maestro y por lo tanto, cada una de ellas son diferentes puntos críticos en la adaptación de un trabajo protésico. Conclusiones: Los modelos definitivos obtenidos con la siliconas por condensación vaciados a las 0.5 horas de haber tomado la impresión, presentan menor alteración dimensional en comparación a los otros grupos. Se puede afirmar que, a mayor tiempo de vaciado, existe una mayor alteración dimensional. Sin embargo, tampoco es recomendable realizarlo inmediatamente después de haber tomado la impresión porque el material no se ha recuperado aun elásticamente y necesita estabilizarse.
      Acceso abierto
    • Comparación in vitro de la estabilidad cromática de dos marcas de resinas bulk fill sometidas a diferentes sustancias pigmentantes

      Cafferata Montoya, Paola; Salas Cusihuaman, Nancy Yudith; Castro Leyva, Iris Lucero (Universidad Peruana de Ciencias Aplicadas (UPC), 2018-12-03)
      Materiales y métodos : Se evaluaron 60 discos de resina (6 mm de diámetro y 4 mm de altura) de cada marca: FiltekTM Bulk Fill -3M-ESPE y Tetric N-Ceram® Bulk Fill Ivoclar-Vivadent, divididas en 4 grupos según sustancias pigmentantes, chicha morada, té verde, té de coca y agua destilada (Grupo control) por 14 días. Los especímenes fueron inmersos en 20 ml de sustancias diariamente a temperatura de 37C±5°. La evaluación del color se realizó a las 24 horas, 7 y 14 días, utilizando un espectrofotómetro Vita Easyshade® Advance 4.0, para hallar los valores de ΔE, L, C, H, a* y b*. Se utilizó la prueba de Kruskal Wallis para comparar los valores de la estabilidad cromática. Resultados : La mayor variación de color fue presentada por la resina Tetric N-Ceram®, al ser sumergida en todas las sustancias pigmentantes y todos los intervalos de tiempo. Al comparar ΔE se observo que la resina FiltekTM presentó 11.39±1.81, 8.47±2.14 y 7.90±1.81 y la resina Tetric N-Ceram® presentó 9.29±1.29, 5.58±1.96 y 4.39±1.59 siendo sometidas en chicha morada, té verde y té de coca. En la evaluación de la luminosidad se observó que la resina FiltekTM presentó 63.06±.75, 61.27±1.55 y 61.27±2.19 y la resina Tetric N-Ceram® presentó 64.79±3.32, 68.44±.86 y 67.51±1.11 cuando fueron sumergidas en las sustancias pigmentantes.
      Acceso abierto
    • Comparación in vitro de la fuerza de adhesión de postes de fibra de vidrio con superficie tratada previo a su cementación con un agente resinoso autograbante

      Revoredo De Rojas, Arturo; Sánchez Ríos, Fiorella; Torres Rivera, Juan Miguel (Universidad Peruana de Ciencias Aplicadas (UPC), 2018-01-23)
      Objective: This in vitro study compared the fiberglass posts bond strength treated with differents surface treatments before their cementation. Materials and Methods: Forty bovine teeth were seccionated in two, obtaining 21mm bovine roots. Bovine roots were endodontically treated and randomly divided into four groups according to the surface treatment of the post: Group 1 (Silane), Group 2 (Phosphoric Acid, Silane), Group 3 (Hydrogen Peroxide, Silane) and Group 4 (Silane, Adhesive). After that, the fiber posts were cemented with a resin agent (RelyX U200 - 3M ESPE), according manufacturer instructions and the samples were stored for 24 hours in distilled water at 37 °C. Roots were cut in slides in a digital cutting machine in order to obtain a 1 mm sample. Push out test was used to measure the bond strength at the speed of 0.5 mm/min. Results: The adhesion strength of the groups did show differences in their medians (p = 0.010). In the pairwise comparisons where it was using the Kruskal Wallis test, the (Group 1 vs. Group 3), (Group 1 vs. Group 4), (Group 2 vs. Group 3), and (Group 2 vs. Group 4) did found statistically significant differences (p = 0.010, p = 0.004, p = 0.009, p = 0.019).In the other pairwise comparisons using the posthoc of kruskall wallis test, the (Group 1 vs. Group 2), and (Group 3 vs. Group 4), were no found statistically significant differences (p = 0.394 and p = 0.387),so the Group 3 and Group 4 had higher adhesion forces (median of 3.49 MPa and 4.13 MPa respectively). Conclusion: The surface treatment of the fiberglass post, with Hydrogen Peroxide with Silane, and Silane with Adhesive obtained better results of adhesive strength.
      Acceso abierto
    • Comparación in vitro de la fuerza de adhesión de postes de fibra de vidrio tratados con silano en distintos tiempos de evaporación del solvente

      Revoredo De Rojas, Arturo; Figueroa Yamunaqué, Elena (Universidad Peruana de Ciencias Aplicadas (UPC), 31/05/2016)
      Objective: To compare the fiberglass posts bond strength treated with silane at different solvent evaporation times. Materials and Methods: Forty bovine teeth were seccionated in two, obtaining 20mm bovine roots. Bovine roots were endodontically treated and randomly divided into four groups according to evaporation time (n=10): G1-180 seconds; G2-120 seconds; G3- 60 seconds; G4-control, without silanizing. Prosil – FGM silane was applied to the post surface and was allowed to evaporate according to the time established in the experimental groups. After that, the fiber posts were cemented with RelyX U-200TM – 3M ESPE resin cement according to manufacturer instructions and the samples were stored 24 hours in distilled water at 37 °C. Roots were cut in slides 1 mm thick using a IsoMet® - Low Speed Saw digital cutting machine. Push-out test was used to measure the slide bond strength in KgF/MPa at the speed of 0.5 mm/min. Results: The bond strength values according to each group were: G1-10.89±2.68; G2-5.50±2.84; G3-2.40± 0.89; G4-0.79±0.73. Bond strength was compared between experimental groups 60-120 seconds, 120-180 seconds and 60-180 seconds. Statistically significant differences were found for all three groups (p=0.0015, p=0.0015 and p=0.0000, respectively). Statistically significant differences were also found between the three groups (p=0.0001). Conclusion: The 180 seconds evaporation group showed a higher bond strength compared with the other groups.
      Acceso abierto