Evaluacion in vitro de la rugosidad superficial de la resina compuesta Filtek Z350 XT utilizando tres sistemas de pulido: Jiffy® (Ultradent), Optimize® (TDV) y Sof-Lex Spiral™ (3M ESPE)
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Authors
Bautista Loayza, Lineth AngélicaAdvisors
Hermoza Novoa, MónicaIssue Date
2016-12-14
Metadata
Show full item recordAbstract
Objetivo: Evaluar in vitro la rugosidad superficial de una resina compuesta nanoparticulada Filtek Z350 XT (3M ESPE) sometida a tres diferentes sistemas de pulido. Materiales y métodos: Se realizó un estudio experimental in vitro. Se confeccionaron 24 cuerpos de prueba (15mm x 15mm x 3mm) con resina compuesta Filtek Z350 XT (3M ESPE, St. Paul, MN, USA). Estos fueron almacenados en agua destilada a 37ºC por 24 horas y divididos aleatoriamente en tres grupos de 8. La rugosidad superficial de las muestras fue determinada por un rugosímetro (TRI 00 Surface Roughness Tester). Después, cada grupo fue sometido a los procedimientos de acabado y pulido: Grupo I: Jiffy® (Ultradent); Grupo II: Optimize® (TDV) y Grupo III: Sof-Lex Spiral™ (3M ESPE, St. Paul, MN, USA). El tiempo de pulido fue de 30 segundos por cada caucho del sistema correspondiente. Después, fue realizada la lectura final. Los datos fueron analizados por la prueba t de Student y ANOVA (p<0.05). Resultados: Se encontraron diferencias estadísticamente significativas entre los sistemas de pulido. El grupo I mostró una diferencia en la rugosidad de 0.118μm ± 0.066; el grupo II: 0.278 ± 0.088 µm; y el grupo III: 0.216 μm ± 0.030. Conclusión: El uso del sistema de pulido Jiffy® (Ultradent) ofrece una mejor lisura superficial de una resina compuesta en relación a otros sistemas de pulido.Aim: To evaluate in vitro the surface roughness of a composite resin submitted to different polishing systems. Materials and Methods: Twenty four specimens were prepared (15 mm x 15 mm x 3 mm) with resin composite Filtek Z350 XT (3M ESPE, St. Paul, MN, USA)). The specimens were stored in distilled water at 37°C for 24 hours and randomly divided into three groups of 8. The surface roughness of the samples was determined with a mechanical roughness tester (TRI 00 Surface Roughness Tester). Then, each group was subjected to finishing and polishing procedures: Group I: Jiffy® (Ultradent); Group II: Optimize® (TDV); Group III: Sof-Lex spiral ™ (3M ESPE, St. Paul, MN, USA). The polishing time was 30 seconds for each instrument. Then, it was made the final reading. The data were analyzed by t-Student test and ANOVA (p<0.05). Results: There were statistically significant differences found between polishing systems. Group I showed a roughness of 0.118μm ± 0.066; Group II: 0.278 ± 0.088 µm; and group III: 0.216 μm ± 0.030. Conclusion: The use of Jiffy® polishing system (Ultradent) provides a better surface smoothness of a composite relative to other polishing systems resin.
Type
info:eu-repo/semantics/bachelorThesisRights
info:eu-repo/semantics/embargoedAccessLanguage
spaCollections
The following license files are associated with this item:
- Creative Commons
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/embargoedAccess